Skip to content
Call (803) 220-0101
3625 Centre Circle, Ste C
Fort Mill, SC 29715

01Case study · Industrial printing

Holding 55% RH Across Six Buildings of a North Carolina Printing Company

Over a six-year period, GoFog humidified six buildings for a large printing company in North Carolina with in-room fog systems. More than 440,000 sq ft of production space, under ceilings from 20 to 35 ft high, is held at 72°F and 55% RH within ±2% RH by 19 separately controlled zones delivering over 12,000 lbs/hr. GoFog provided the reverse osmosis water treatment for every building and installed the systems.

GoFog, Inc. Case study North Carolina In-room industrial humidification 5 min read

A GoFog fog nozzle on a curved stainless steel riser sprays a plume of fine fog into the open space beneath an industrial roof with steel joists, lights, hoses and a fabric air duct
In-room GoFog nozzle fogging directly into the production space
Buildings humidified by GoFog
6buildings
Space humidified
440,000+sq ft
Total humidification capacity
12,000+lbs/hr
Separately controlled zones
19zones
Setpoint held at 72°F, within ±2% RH
55% RH
Ceiling heights
20–35ft

01The project

What was the project?

The customer is a large printing company with operations in North Carolina. Over a six-year period, GoFog humidified six of its buildings, more than 440,000 sq ft of space in total.

These are in-room systems: the fog nozzles are installed in the production space itself, not inside air handling units. The buildings have ceiling heights from 20 to 35 ft, and every building is held at 72°F and 55% RH, within ±2% RH.

GoFog supplied the complete system for each building: the reverse osmosis water treatment, the pump units, the zone controls and the nozzle lines, and GoFog installed it.

02Why printing needs humidity

Why does a printing plant need controlled humidity?

Paper is hygroscopic: it absorbs and releases moisture as the air around it changes. When the air is dry, paper gives up moisture, builds static and curls. Sheets become hard to separate, and curl leads to creasing and mis-feeds that stop the presses.

Ink suffers too. Clogged heads, nozzle dropout and poor ink transfer increase noticeably in winter, when heating drives the relative humidity inside a building below recommended levels.

Holding the pressroom at a steady humidity keeps paper at a stable moisture content, so presses can run at higher speeds with fewer rejects. That is why this customer specified a tight band, 55% RH ±2%, rather than just "more humidity". Read more about printing humidification.

03The GoFog systems

What did GoFog deliver?

The combined scope of the GoFog systems across the six buildings.

Project scope · NC printing company
GoFog in-room humidification for a printing company in North Carolina
ItemDelivered
Buildings6 buildings humidified by GoFog over a 6-year period
Space humidifiedOver 440,000 sq ft
System typeIn-room (direct) fog humidification, ceiling heights from 20 to 35 ft
Humidification capacityOver 12,000 lbs/hr in total
Zones19 zones, each controlled separately
Conditions held72°F and 55% RH, within ±2% RH
Water treatmentReverse osmosis, provided by GoFog for every building
InstallationInstalled by GoFog

04In-room fog and zones

How does an in-room fog system hold ±2% RH?

A GoFog pump unit with a touchscreen control panel, Pump A and Pump B drives and blue filter housings, beside a wall rack of motorized zone valves feeding stainless steel tubing, while a technician works on the tubing behind it
GoFog pump unit and motorized zone valves during installation

In an in-room system, the fog is made where the humidity is needed. A GoFog pump unit raises purified water to 1,000 psi and sends it through stainless steel tubing to nozzle lines in the production space. Each nozzle breaks the water into droplets less than 20 microns in size, which evaporate in the room air and raise its humidity directly.

Across the six buildings, the space is divided into 19 zones, each controlled separately. A zone has its own valve, so it fogs only when its own humidity falls below setpoint. Different areas of a plant lose moisture at different rates, depending on equipment, doors and airflow, and controlling each zone on its own demand is what keeps the whole floor within ±2% RH of 55%, rather than over-wetting one area to bring another up.

The nozzle lines are laid out for ceilings from 20 to 35 ft high, so the fog has room to evaporate fully before it reaches the presses, the paper or the people working below.

05Water treatment

Why reverse osmosis water for a printing plant?

A water treatment room on a yellow containment pad: twin water softener tanks and a brine tank, a blue-framed reverse osmosis skid, a tall blue storage tank and a GoFog pump unit, with a technician checking the white feed piping
Softeners, RO skid, storage tank and GoFog pump unit

GoFog provided the reverse osmosis water treatment for every building. When fog evaporates, anything dissolved in the water is left behind. With untreated water, that would be a fine mineral dust settling on the paper, the presses and the finished product.

RO removes those minerals before the water reaches the pump units, so the fog evaporates clean. It also protects the nozzles: purified water keeps the small orifices from scaling, which keeps the droplet size, and the humidity control, consistent over time.

06Six buildings, six years

How was the project delivered?

The six buildings were humidified over a six-year period, and GoFog installed the systems. Delivering building by building let the customer add humidification to each part of the operation in turn, with the same water treatment, pump units and controls in every building.

Today the six buildings share one standard: 72°F and 55% RH, held within ±2% RH by 19 zones and more than 12,000 lbs/hr of fog. The same team that builds GoFog equipment in Fort Mill, South Carolina, supports it after start-up with spare parts and service.

Planning humidification for a pressroom, plant or warehouse? Contact GoFog or call (803) 220-0101 for a system design and free quote.

07FAQ

Printing plant humidification FAQ

How much space does GoFog humidify for the printing company?

More than 440,000 sq ft across six buildings, with ceiling heights from 20 to 35 ft and over 12,000 lbs/hr of humidification in total.

What conditions do the systems hold?

72°F and 55% relative humidity, held within ±2% RH.

How many zones are there?

Nineteen zones, each controlled separately, so every area fogs only when its own humidity drops below setpoint.

What is an in-room humidification system?

An in-room, or direct, system installs the fog nozzles in the space itself rather than inside an air handling unit. The fog evaporates in the room air and raises its humidity directly.

Who provided the water treatment and installation?

GoFog did both. GoFog provided reverse osmosis water treatment for all six buildings and installed the systems over a six-year period.

Steady humidity for every press.